Korean Journal of Radiology ; : 274-283, 2023.
Article in English | WPRIM | ID: wpr-968240

ABSTRACT

Objective@#To compare the outcomes of digital breast tomosynthesis (DBT) screening combined with ultrasound (US) with those of digital mammography (DM) combined with US in women with dense breasts. @*Materials and Methods@#A retrospective database search identified consecutive asymptomatic women with dense breasts who underwent breast cancer screening with DBT or DM and whole-breast US simultaneously between June 2016 and July 2019. Women who underwent DBT + US (DBT cohort) and DM + US (DM cohort) were matched using 1:2 ratio according to mammographic density, age, menopausal status, hormone replacement therapy, and a family history of breast cancer. The cancer detection rate (CDR) per 1000 screening examinations, abnormal interpretation rate (AIR), sensitivity, and specificity were compared. @*Results@#A total of 863 women in the DBT cohort were matched with 1726 women in the DM cohort (median age, 53 years; interquartile range, 40–78 years) and 26 breast cancers (9 in the DBT cohort and 17 in the DM cohort) were identified. The DBT and DM cohorts showed comparable CDR (10.4 [9 of 863; 95% confidence interval {CI}: 4.8–19.7] vs. 9.8 [17 of 1726;95% CI: 5.7–15.7] per 1000 examinations, respectively; P = 0.889). DBT cohort showed a higher AIR than the DM cohort (31.6% [273 of 863; 95% CI: 28.5%–34.9%] vs. 22.4% [387 of 1726; 95% CI: 20.5%–24.5%]; P < 0.001). The sensitivity for both cohorts was 100%. In women with negative findings on DBT or DM, supplemental US yielded similar CDRs in both DBT and DM cohorts (4.0 vs. 3.3 per 1000 examinations, respectively; P = 0.803) and higher AIR in the DBT cohort (24.8% [188 of 758; 95% CI: 21.8%–28.0%] vs. 16.9% [257 of 1516; 95% CI: 15.1%–18.9%; P < 0.001). @*Conclusion@#DBT screening combined with US showed comparable CDR but lower specificity than DM screening combined with US in women with dense breasts.

2.
Journal of Breast Cancer ; : 25-36, 2022.
Article in English | WPRIM | ID: wpr-925173

ABSTRACT

Purpose@#To evaluate the axillary recurrence rate and usefulness of axillary ultrasound (AUS) during supplementary whole-breast ultrasound (US) screening in women with a personal history of breast cancer (PHBC). @*Methods@#A retrospective database search identified consecutive asymptomatic women who underwent postoperative supplemental whole-breast US screening, including that of the bilateral axillae, after negative findings on mammography between January and June 2017. Using the pathologic data or at least 1-year follow-up data as reference standards, the axillary recurrence rate, cancer detection rate (CDR), interval axillary recurrence rate per 1,000 screenings, sensitivity, specificity, and abnormal interpretation rate (AIR) were estimated. @*Results@#From the data of 4,430 women (mean age, 55.0 ± 10.1 years) analyzed in this study, there were five axillary recurrence cases (1.1/1,000) in the median follow-up period of 57.2 months. AUS showed a CDR of 0.2 (1/4,430; 95% confidence interval [CI], 0.01–1.3) and an interval axillary recurrence rate of 0.9 (4/4,402; 95% CI, 0.2–2.3) per 1,000 examinations. The sensitivity and specificity were 20.0% (1/5; 95% CI, 0.5–71.6), and 99.4% (4,398/4,425; 95% CI, 99.1–99.6), respectively, while the AIR was 0.6% (28/4,430; 95% CI, 0.4–0.9%). @*Conclusion@#In asymptomatic women with a PHBC and negative findings on mammography, axillary recurrence after breast cancer and axillary treatment was uncommon, and the supplemental AUS screening yielded 0.2 cancers per 1,000 examinations.

3.
Journal of Breast Cancer ; : 554-560, 2021.
Article in English | WPRIM | ID: wpr-914826

ABSTRACT

Axillary ultrasonography (US) is the most commonly used imaging modality for nodal evaluation in patients with breast cancer. No Axillary Surgical Treatment in Clinically Lymph Node-Negative Patients after Ultrasonography (NAUTILUS) is a prospective, multicenter, randomized controlled trial investigating whether sentinel lymph node biopsy (SLNB) can be safely omitted in patients with clinically and sonographically node-negative T1–2 breast cancer treated with breast-conserving therapy. In this trial, a standardized imaging protocol and criteria were established for the evaluation of axillary lymph nodes. Women lacking palpable lymph nodes underwent axillary US to dismiss suspicious nodal involvement.Patients with a round hypoechoic node with effaced hilum or indistinct margins were excluded. Patients with T1 tumors and a single node with a cortical thickness ≥ 3 mm underwent US-guided biopsy. Finally, patients with negative axillary US findings were included. The NAUTILUS axillary US nodal assessment criteria facilitate the proper selection of candidates who can omit SLNB.

4.
Journal of Korean Medical Science ; : e22-2020.
Article in English | WPRIM | ID: wpr-892093

ABSTRACT

BACKGROUND@#Central dark-signal intensity with high-signal, hypertrophic mucosal wall of paranasal sinuses on T2-weighted images (T2WI) is a characteristic magnetic resonance imaging (MRI) feature of sinonasal fungus ball. However, this finding is usually interpreted as non-fungal chronic sinusitis with central normal sinus air. In addition, T1-weighted images (T1WI) and T2WI are basic sequences of all magnetic resonance (MR) examinations. Therefore, we evaluated the usefulness of T1WI for detecting fungus balls comparing with computed tomography (CT) findings and T2-weighted MRI findings.@*METHODS@#This retrospective study was approved by the Institutional Review Board of Korea University Guro Hospital. Two reviewers assessed preoperative CT and MR images of 55 patients with pathologically confirmed fungus balls. Reviewers evaluated the presence and patterns of calcifications on CT. Overall signals and the presence and extent of certain signals of fungus balls on MRI were also assessed. The relationship between calcifications and MRI signals was also evaluated.@*RESULTS@#Of the patients, 89.1% had calcifications on CT. All had dark signal portions with high signal, hypertrophic mucosal walls on T2WI. Most (92.7%) patients showed iso- to hyper-intense overall signals on T1WI and 89.1% had T1-weighted high signal portions on MRI. The presence, patterns, and location of calcifications had no significant correlation with T1-weighted high-signal intensity portion.@*CONCLUSION@#Fungus ball can be suggested by the presence of the hyper-signal intensity portions in the fungal mass on T1WI in conjunction with dark-signal lesions surrounded by high-signal, hypertrophic mucosal walls in paranasal sinuses on T2WI.

5.
Korean Journal of Radiology ; : 1210-1219, 2020.
Article | WPRIM | ID: wpr-833572

ABSTRACT

Objective@#To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of handheld ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). @*Materials and Methods@#One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. @*Results@#Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). @*Conclusion@#ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions.

6.
Korean Journal of Radiology ; : 561-571, 2020.
Article | WPRIM | ID: wpr-833516

ABSTRACT

Objective@#To evaluate the clinical utility of ultrafast dynamic contrast-enhanced (DCE)-MRI compared to conventional DCEMRIby studying lesion conspicuity and size according to the level of background parenchymal enhancement (BPE). @*Materials and Methods@#This study included 360 women (median age, 54 years; range, 26–82 years) with 361 who had undergonebreast MRI, including both ultrafast and conventional DCE-MRI before surgery, between January and December 2017. Conspicuitywas evaluated using a five-point score. Size was measured as the single maximal diameter. The Wilcoxon signed-rank test wasused to compare median conspicuity score. To identify factors associated with conspicuity, multivariable logistic regressionwas performed. Absolute agreement between size at MRI and histopathologic examination was assessed using the intraclasscorrelation coefficient (ICC). @*Results@#The median conspicuity scores were 5 at both scans, but the interquartile ranges were significantly different (5-5 atultrafast vs. 4-5 at conventional, p < 0.001). Premenopausal status (odds ratio [OR] = 2.2, p = 0.048), non-mass enhancement(OR = 4.1, p = 0.001), moderate to marked BPE (OR = 7.5, p < 0.001), and shorter time to enhancement (OR = 0.9, p =0.043) were independently associated with better conspicuity at ultrafast scans. Tumor size agreement between MRI andhistopathologic examination was similar for both scans (ICC = 0.66 for ultrafast vs. 0.63 for conventional). @*Conclusion@#Ultrafast DCE-MRI could improve lesion conspicuity compared to conventional DCE-MRI, especially in womenwith premenopausal status, non-mass enhancement, moderate to marked BPE or short time to enhancement.

7.
Journal of Korean Medical Science ; : e22-2020.
Article in English | WPRIM | ID: wpr-899797

ABSTRACT

BACKGROUND@#Central dark-signal intensity with high-signal, hypertrophic mucosal wall of paranasal sinuses on T2-weighted images (T2WI) is a characteristic magnetic resonance imaging (MRI) feature of sinonasal fungus ball. However, this finding is usually interpreted as non-fungal chronic sinusitis with central normal sinus air. In addition, T1-weighted images (T1WI) and T2WI are basic sequences of all magnetic resonance (MR) examinations. Therefore, we evaluated the usefulness of T1WI for detecting fungus balls comparing with computed tomography (CT) findings and T2-weighted MRI findings.@*METHODS@#This retrospective study was approved by the Institutional Review Board of Korea University Guro Hospital. Two reviewers assessed preoperative CT and MR images of 55 patients with pathologically confirmed fungus balls. Reviewers evaluated the presence and patterns of calcifications on CT. Overall signals and the presence and extent of certain signals of fungus balls on MRI were also assessed. The relationship between calcifications and MRI signals was also evaluated.@*RESULTS@#Of the patients, 89.1% had calcifications on CT. All had dark signal portions with high signal, hypertrophic mucosal walls on T2WI. Most (92.7%) patients showed iso- to hyper-intense overall signals on T1WI and 89.1% had T1-weighted high signal portions on MRI. The presence, patterns, and location of calcifications had no significant correlation with T1-weighted high-signal intensity portion.@*CONCLUSION@#Fungus ball can be suggested by the presence of the hyper-signal intensity portions in the fungal mass on T1WI in conjunction with dark-signal lesions surrounded by high-signal, hypertrophic mucosal walls in paranasal sinuses on T2WI.